Protecta III Zone 1 LED

 

(PRGE – Standard & Emergency)
The Protecta III LED Linear delivers to the Industry unparalleled performance and photometric’s

Need help finding something? We're here to assist you. Call 031-84 03 00.

    SKU: PRGE/02L/LE 2178, PRGE/05L/LE 4607, PRGE/02L/LE/EM 2178, PRGE/05L/LE/EM 4 Categories: , , Tags: ,

    Description

    The Protecta III LED Linear delivers to the Industry unparalleled performance and photometric’s bringing forward all the recognised benefits of the Protecta range; a proven robust enclosure, excellent IP and low maintenance features. Expected useful life to 70% of the initial lumens (L70) is a market leading 120,000 hours at 25°C. With fully replaceable LED strips and driver we deliver a unique product with effective long term maintenance capability.

    • Highly Energy efficient.
    • Full length easy access diffuser clamp.
    • Screwless mains terminals.
    • DTS-01 deluge tested.

    The Protecta III LED Luminaires added features finds high application in the field of Industrial and Oil & Gas Industry.

    Technical Data

    General

    Application
    • Zone 1 and 21
    • Surface Mount
    ATEX Classification
    Group II Category 2 GD
    Battery Type
    6V 4Ah & 7Ah Nickel Cadmium (NiCAD)
    Construction Material – Main
    GRP (Glass Reinforced Plastic)
    Emergency Illumination Time
    90 min
    Ingress Protection
    • IP66/67
    • IK10
    Lamp Type
    LED
    Light Source
    LED Strips
    Material
    GRP body with polycarbonate cover.
    Operating Temperature Range Celcius
    -40°C to +55°C
    Style
    Linear
    Type
    Linear

    Certifications And Compliance

    ATEX File Number
    Baseefa04ATEX0220
    Certified Listed
    • ATEX
    • IEC Ex
    • Inmetro
    • EAC (Russian)
    Compliance
    • Increased Safety, Encapsulation, Powder Filling
    • IP66/67
    • IK10
    Hazardous Rating(s)
    • Ex e mb op is q IIC T4 Gb
    • Ex mb op is tb IIIC T95°C Db IP6X
    Industry Standard(s)
    • EN 60079-10
    • IEC 50281-3
    • EN 60079-14
    • IEC 50281-1-2