GMI D5014D Isolators

I.S. SIL3 2/4-Wire HART® Transmitter Power Supply

    SKU: D5014D, D5014 Categories: , Tags: ,

    Description

    The Repeater Power Supply D5014 module is a high integrity analog input interface suitable for applications requiring SIL 3 level in safety related systems for high risk industries. It provides a fully floating dc supply for energizing conventional 2 wires 4-20 mA, active or passive, transmitters located in Hazardous Area, and repeats the current in floating circuit to drive a Safe Area load. The module supports output current duplication and it allows bi-directional communication signals, for HART® devices.

    FEATURES

    • SIL 3 / SC 3
    • Input from Zone 0/Div. 1
    • Installation in Zone 2/Div. 2
    • 2 fully independent channels
    • 4-20 mA Active-Passive Input, Source-Sink Output
    • Output current duplication available
    • HART® compatible
    • Input and Output short circuit proof
    • In-field programmability by DIP Switch
    • High Accuracy
    • Three port isolation, Input/Output/Supply
    • High Density, two channels per unit

    CHANNELS

    2

    Technical data

    Supply

    Voltage 24 Vdc nom (18 to 30 Vdc), reverse polarity protected
    Current Consumption 90 mA @ 24 Vdc with 20 mA out, typical.
    Power Dissipation 1.35 W @ 24 Vdc with 20 mA out, typical.

    Input

    Type 4 to 20 mA (separately powered input, voltage drop ≤ 0.5 V) or 4 to 20 mA (2 wires Tx current limited ≈ 25 mA), reading range 0 to 24 mA.
    Transmitter line voltage 15.0 V typical, 14.5 V minimum, @ 20 mA.

    Output

    Type 4 to 20 mA, on max. 550 Ω load in source mode (typical 12 V compliance); V min. 8 V @ 0 Ω load V max. 30 V in sink mode, current limited ≈ 25 mA or 1 to 5 V on internal 250 Ω shunt. Output current duplication available (D5014D).
    Response time 5 ms (0 to 100 % step change).

    Performance

    Ref. Conditions 24 V supply, 250 Ω load, 23 ± 1 °C ambient temperature.
    Calibration accuracy ≤ ± 0.1 % FSR.
    Linearity accuracy ≤ ± 0.05 % FSR.
    Temp. influence ≤ ± 0.01 % FSR on zero/span for a 1 °C change.

    Isolation

    Test Voltage I.S. In/Out 2.5 kV; I.S. In/Supply 2.5 kV; I.S. In/I.S. In 500 V; Out/Supply 500 V; Out/Out 500 V.

    Environmental conditions

    Operating temperature temperature limits –40 to +70 °C.
    Storage temperature temperature limits –45 to +80 °C.

    Safety description

    Equipment Associated apparatus and non-sparking electrical equipment.
    Safety parameters Uo = 25.9 V, Io = 92 mA, Po = 594 mW at terminals 7-8, 9-10. Uo = 1.1 V, Io = 56 mA, Po = 16 mW at terminals 8-11, 10-12. Ui = 30 V, Ii = 128 mA, Ci = 0 nF, Li = 0 nH at terminals 8-11, 10-12. Um = 250 Vrms or Vdc, -40 °C ≤ Ta ≤ 70 °C.

    Mounting

    Type DIN-Rail 35 mm, with or without Power Bus or on custom Term. Board.
    Weight about 155 g
    Connection by polarized plug-in disconnect screw terminal blocks to accommodate terminations up to 2.5 mm² (13 AWG).
    Dimensions Width 12.5 mm, Depth 123 mm, Height 120 mm.

    Download

    Datasheet ED5014D

    Instruction manual, 5014S-5014D

    Instruction manual, D5000 – D5200 Series

    G.M. International srl