Ex ZS 80 1Ö/1S WVD – 3m

 

Ex emergency pull-wire switch

    Description

    • Ex zone 1 and 21
    • Metal enclosure
    • 2 contacts
    • Position indicator and integrated emergency-stop push button
    • Wire length up to 100 m
    • Spring force variant: 100 N
    • Lever for release and position indication
    • Watertight collar
    • Wire pull and breakage detection
    • Attention: Please state required international approvals with your order!

    Notes

    • At 5 m distance intermediate wire supports are required. One wire thimble is provided.

    Technical Data

    Applied standards

    EN 60947-5-1, EN 60947-5-5, EN IEC 60079-0, EN 60079-1, EN 60079-31, EN ISO 13850, EN ISO 13849-1

    Enclosure

    aluminium die-cast, enamel finish

    Cover

    thermoplastic, glass-fibre reinforced, shockproof, self-extinguishing UL 94 V-0

    Degree of protection

    IP65 (EN 60079-0 + IEC/EN 60529), IP67 (IEC/EN 60529)

    B10d (10 % load)

    200 000

    TM

    max. 20 years

    Switch insert

    1 x Ex 14

    Contact material

    silver

    Switching system

    slow action, positive break NC contacts A

    Switching elements

    1 NC/1 NO contact, type Zb

    Connection

    pre-wired cable H05VV-F

    Cable cross-section

    4 x 0.75 mm² (incl. conductor ferrules)

    Cable length

    3 m

    Rated impulse withstand voltage Uimp

    4 kV

    Rated insulation voltage Ui

    250 V

    Conventional thermal current Ithe

    T6: 6 A, T5: 3 A

    Utilisation category

    AC-15; DC-13

    Rated operating current/voltage Ie/Ue

    6 A/250 VAC; 0.25 A/230 VDC

    Short-circuit protection

    6 A gG/gN fuse

    Ambient temperature

    T6: –20 °C … +65 °C,
    T5: –20 °C … +75 °C, +90 °C with max. 3 A

    Mechanical life

    > 100 000 operations

    Max. wire length

    100 m

    Impact energy

    max. 7 J

    Ex marking

    L II 2G Ex d IIC T6/T5 Gb,
    L II 2D Ex tb IIIC T80 °C/T95 °C Db
    IECEx Ex d IIC T6/T5 Gb,
    Ex tb IIIC T80 °C/T95 °C Db

    Approvals

    PTB 11 ATEX 1003 X
    IECEx PTB 07.0034 X
    f d a

    Weight

    964 g