387 | Ex e | Dome Head Stopping plug

387 Stopping Plugs are manufactured in Brass (standard), Nickel Plated Brass or 316 Stainless Steel. ATEX/IECEx approved Exe/Ext

    Description

    The Hawke 387 dome headed stopping plug is a metallic NPT fitting designed to blank unused openings on thin walled hazardous area enclosures, using an NPSL locknut. Dual Certified ATEX/IECEx (along with many more) for use in Increased Safety (Exe) and Dust (Ext) protection concepts.

    • Metallic construction
    • Certified Exe/Ext
    • NPT mounting thread options
    • Integral Nitrile or Silicone O-Ring – Maintains IP66 & IP67

    387 Stopping Plugs are manufactured in Brass (standard), Nickel Plated Brass or 316 Stainless Steel.

     

    Technical data

    General

    Application
    Hazardous Areas Zone 1, Zone 21, Zone 2, Zone 22
    Ingress Protection
    IP66, IP67 to IEC/EN 60529
    Material
    Manufactured in Brass (Standard), Nickel Plated Brass or 316L Stainless Steel
    Operating Temperature
    • -60°C to +80°C (with Nitrile O-Ring)
    • -60°C to +160°C (with Silicone O-Ring)
    Series
    Fittings for Hazardous Areas

    Certifications And Compliance

    Certification
    • ATEX: Baseefa 06ATEX0118U
    • cCSAus: 2700364
    • EAC: No EA3C RU C-GB.HA91.B.00265/21
    • EQM: 20-11-27224/Q20-11-000979/NB0007
    • IECEx: BAS06.0029U
    • Inmetro: IEx 15.0292U
    • SONCAP: LCOGB049552-0500
    • UKEx: BAS21UKEX0051U
    Hazardous Rating(s)
    • Ex II 2GD Ex eb IIC Gb
    • Ex tb IIIC Db
    • Class 1 Zone 1 AEx eb IIC Gb
    • Zone 21 AEx tb IIIC Db
    Industry Standard(s)
    IEC/EN/CSA/UL 60079-0, 7, 31CSA C22.2 No 0-10