    The Multifunction Temperature Converter D5072 accepts a low level dc signal from millivolt, thermocouple or 2-3-4 wire resistance/RTD or transmitting potentiometer sensor, located in Hazardous Area, and converts, with isolation, the signal to drive a Safe Area load, suitable for applications requiring SIL 2 level in safety related systems for high risk industries. Output signal can be direct or reverse. Modbus RTU RS-485 output is available on Bus connector. Cold junction compensation can be programmed as Internal: provided by an internal temperature sensor; Fixed: to a user-customizable temperature value; Remote: (only D5072D) connecting compensation RTD to one of the two ch. For D5072D module: duplicator function provides two independent outputs from one single input. Output function can be configured as: Adder, subtractor, low/high selector. Modules are provided with alarm function, which is available via photoMOS output.

    FEATURES

    • SIL 2 / SC 3
    • Input from Zone 0/Div. 1
    • Installation in Zone 2/Div. 2
    • mV, TC, 2/3/4wire res./RTD or potentiometer input
    • Duplication/inversion/scaling/custom output
    • Selectable CJC: internal PT1000, external RTD or fixed
    • Fastest integration time: 50 ms
    • Burnout/internal/cjc/in sensor fault monitor
    • Alarm output with user-settable trip points
    • Modbus RTU RS-485 for monitor & configuration
    • Fully programmable operating parameters
    • High Accuracy, µP controlled A/D converter
    • Three port isolation, Input/Output/Supply
    • High Density, two channels per unit

    CHANNELS

    2

    Technical data

    Supply

    Voltage 24 Vdc nom (18 to 30 Vdc), reverse polarity protected
    Current Consumption 50 mA @ 24 Vdc with 20 mA out, typical.
    Power Dissipation 1.0 W @ 24 Vdc with 20 mA out, typical.

    Input

    Type Millivolt, thermocouple, 2-3-4 wire RTD or 3 wire transmitting potentiometer. Refer to Instruction Manual for more details.
    Integration time from 50 ms to 500 ms.
    Input range ±500 mV (TC/mV), 0-4 kΩ (RTD/res), up to 10 kΩ (pot).
    Thermocouple reference junction compensation programmable: internal Pt1000, fixed, external, or remote.

    Output

    Type Fully customizable 0/4 to 20 mA, on max. 300 Ω load source mode, current limited @ 24 mA. Refer to Instruction Manual for more details.
    Transfer characteristic linear, direct or reverse on all input sensors.

    Modbus interface

    Type Modbus RTU RS-485 up to 115.2 kbps for monitor/configuration/control.

    Input performance

    Ref. Conditions 24 V supply, 250 Ω load, 23 ± 1 °C ambient temperature, slow integration mode, 3/4 wires configuration for RTD.
    Calibration and linearity accuracy refer to Instruction Manual.
    Temp. influence refer to Instruction Manual.
    Ref. junction compensation accuracy ≤ ± 1 °C.

    Output performance

    Ref. Conditions 24 V supply, 250 Ω load, 23 ± 1 °C ambient temperature, slow integration mode, 3/4 wires configuration for RTD.
    Calibration accuracy ≤ ± 10 µA
    Linearity error ≤ ± 10 µA.
    Temp. influence ≤ ± 2 µA/°C

    Isolation

    Test Voltage I.S. In/Out 2.5 kV; I.S. In/Supply 2.5 kV; I.S. In/I.S. In 500 V; Out/Supply 500 V; Out/Out 500 V.

    Environmental conditions

    Operating temperature temperature limits –40 to +70 °
    Storage temperature temperature limits –45 to +80 °C.

    Safety description

    Equipment Associated apparatus and non-sparking electrical equipment.
    Safety parameters Uo = 7.2 V, Io = 16 mA, Po = 27 mW, Ui = 12.8 V, Ci = 0 nF, Li = 0 nH at terminals 7-8-9, 10-11-12. Um = 250 Vrms or Vdc, -40 °C ≤ Ta ≤ 70 °C.

    Mounting

    Type DIN-Rail 35 mm, with or without Power Bus or on custom Term. Board.
    Weight about 135 g
    Connection by polarized plug-in disconnect screw terminal blocks to accommodate terminations up to 2.5 mm² (13 AWG).
    Dimensions Width 12.5 mm, Depth 123 mm, Height 120 mm.