501/414 | Ex d & Ex e | Cable Gland
The Hawke 501/414 is a Group II certified single seal cable gland, with a female running coupler, suitable for installation in Zone 1/21 and Zone 2/22 hazardous areas.
Description
The Hawke 501/414 is a Group II certified single seal cable gland, with a female running coupler, suitable for installation in Zone 1/21 and Zone 2/22 hazardous areas. Dual Certified ATEX/IECEx (along with many more) for use in Increased Safety (Exe), Flameproof (Exd), Restricted Breathing (ExnR) and Dust (Ext) protection concepts. For use with non-armoured elastomer and plastic insulated cables installed in conduit. This cable gland may be used with braided cables where the braid and outer sheath pass into the enclosure, and the requirements of 60079-14 are met.
- Single elastomeric Exd compression seal on cable outer sheath
- Female threaded running coupler for cable gland or conduit entry
- Available with metric or NPT entry and female threadforms
Technical data
Applikacion | Hazardous Areas Zone 1, Zone 21, Zone 2, Zone 22 |
Ingress Protection
|
IP66 and IP67 |
Material |
Manufactured in Brass, Nickel Plated Brass or 316L Stainless Steel
|
Operating Temperature
|
-60°C to +100 °C |
Series | Group II Hazardous Areas |
Certificat etc.
ATEX File Number | CML 19ATEX1167X CML 19.0045X |
CSA File Number | CSA1015065 |
Certification |
|
Hazardous Rating(s) |
|
Industry Standard(s) |
|
Ratings | IK10 to IEC 62262 |