Ex 13 WR 1Ö/1S – 5m

Ex position switch with safety function

    SKU: 23661, 1045064 Categories: , Tag:

    Description

    • Ex zone 1 and 21
    • Thermoplastic enclosure
    • Double insulated X
    • Suitable for in-line mounting
    • With pre-wired cable
    • Actuator: Roller plunger with collar WR
    • Actuating speed max. 0.5 m/s with a vertical actuating angle of 25°
    • Metal roller
    • Watertight collar for protection against penetration of dirt
    • Attention: Please state required international approvals with your order!

    Notes

    • Actuator can be repositioned by 90° on request

    Technical data

    Applied standards

    EN 60947-5-1, EN IEC 60079-0, EN 60079-1, EN 60079-31, EN ISO 13849-1, EN ISO 14119

    Enclosure

    thermoplastic, glass-fibre reinforced, shockproof, self-extinguishing UL 94 V-0

    Switch type

    type 1

    Coding level

    no coding

    Degree of protection

    IP65 (EN 60079-0 + IEC/EN 60529), IP67 (IEC/EN 60529)

    B10d (10 % load)

    2 million

    TM

    max. 20 years

    Contact material

    silver

    Switching system

    slow action, positive break NC contacts A

    Switching elements

    1 NC/1 NO contact, type Zb

    Connection

    pre-wired cable H05VV-F

    Cable cross-section

    4 x 0.75 mm² (incl. conductor ferrules)

    Cable length

    5 m

    Rated impulse withstand voltage Uimp

    4 kV

    Rated insulation voltage Ui

    250 V

    Conventional thermal current Ithe

    T6: 6 A, T5: 3 A

    Rated operating current/voltage Ie/Ue

    6 A/250 VAC; 0.25 A/230 VDC

    Utilisation category

    AC-15; DC-13

    Short-circuit protection

    6 A gG/gN fuse

    Ambient temperature

    T6: –20 °C … +65 °C,
    T5: –20 °C … +75 °C, +90 °C with max. 3 A

    Mechanical life

    > 1 million operations

    Operation cycles

    max. 1800/h

    Repeat accuracy of switching points

    ± 0.1 mm

    Contact opening

    max. 2 x 4 mm

    Impact energy

    max. 7 J

    Ex marking

    L II 2G Ex db IIC T6/T5 Gb,
    L II 2D Ex tb IIIC T80 °C/T95 °C Db
    IECEx Ex db IIC T6/T5 Gb,
    Ex tb IIIC T80 °C/T95 °C Db

    Approvals

    PTB 03 ATEX 1068 X
    IECEx PTB 06.0053X
    f a d Ô

    Weight

    440 g

    Downloads

    Mounting and wiring instructions – Ex 13

    German, English, French, Italian, Portuguese

    Data sheet – Ex 13 WR 1Ö/1S – 5m

    English