487 | Ex d & Ex e | Dome Head Stopping Plug

The 487 tamperproof stopping plug is manufactured in Brass, Nickel Plated Brass, Steel, Nickel Plated Steel and Stainless Steel. (Aluminium for Group II use only). ATEX/IECEx approved Exd/Exe/Ext

Need help finding something? We're here to assist you. Call 031-84 03 00.

    Description

    The Hawke 487 dome headed stopping plug is a metallic fitting designed to blank unused openings on hazardous area enclosures. Dual Certified ATEX/IECEx (along with many more) for use in Flameproof (Exd), Increased Safety (Exe) and Dust (Ext) protection concepts. Also approved for use in Group I Mining Applications.

    • Metallic construction
    • Certified Exd/Exe/Ext
    • Metric mounting thread options
    • Integral Nitrile or Silicone O-Ring – Maintains IP66 & IP67

    The 487 tamperproof stopping plug is manufactured in Brass, Nickel Plated Brass, Steel, Nickel Plated Steel and Stainless Steel. (Aluminium for Group II use only).

    Technical data

    General

    Application
    Hazardous Areas Zone 1, Zone 21, Zone 2, Zone 22 and Mining Applications
     
    Ingress Protection
    IP66, IP67 to IEC/EN 60529
     
    Material
    Manufactured in Brass (Standard), Nickel Plated Brass or 316L Stainless Steel
     
    Operating Temperature
    • -60°C to +80°C (with Nitrile O-Ring)
    • -60°C to +160°C (with Silicone O-Ring)
    Series
    Fittings for Hazardous Areas
     

    Certifications And Compliance

    Certification
    • ABS: 17-LD1653734-PDA
    • ATEX: Baseefa 11ATEX0149X
    • BV: 43523/A1
    • CCC: 2020312313000329
    • cCSAus: 2700364
    • EAC: No EA3C RU C-GB.HA91.B.00265/21
    • EQM: 20-11-27224/Q20-11-000979/NB0007
    • IECEx: BAS11.0071X
    • Inmetro: IEx 15.0208X
    • SONCAP: LCOGB049552-0500
    • UKEx: BAS21UKEX0058X
    Hazardous Rating(s)
    • Ex II 2GD Ex db eb IIC Gb
    • Ex tb IIIC Db
    • Ex I M2 Ex db eb I Mb
    • Class 1 Zone 1 AEx db eb IIC Gb
    • Zone 21 AEx tb IIIC Db
    Industry Standard(s)
    • IEC/EN/CSA/UL 60079-0, 1, 7, 31
    • CSA C22.2 No 0-10
    • IEC 60529